Voltage Drop Formula:
From: | To: |
Definition: This calculator estimates the voltage drop in low-voltage lighting systems based on current, wire length, and wire resistance.
Purpose: It helps electricians and lighting designers ensure proper voltage levels at lighting fixtures in low-voltage systems.
The calculator uses the formula:
Where:
Explanation: The formula accounts for the round-trip path of current (hence the factor of 2) through the conductors.
Details: Proper voltage drop calculation ensures lighting fixtures receive adequate voltage for optimal performance and prevents dimming or flickering.
Tips: Enter the current in amperes, wire length in feet, and wire resistance (default 1.98 ohms/1000 ft for 12 AWG copper). All values must be > 0.
Q1: Why is voltage drop important in low-voltage systems?
A: Low-voltage systems (12V or 24V) are more sensitive to voltage drop than line voltage systems, as even small drops can significantly affect light output.
Q2: What's a typical acceptable voltage drop?
A: Generally, voltage drop should be less than 10% of system voltage (1.2V for 12V systems, 2.4V for 24V systems).
Q3: How do I find wire resistance values?
A: Resistance values are typically: 12 AWG = 1.98 Ω/1000ft, 14 AWG = 3.14 Ω/1000ft, 16 AWG = 4.99 Ω/1000ft (for copper wire).
Q4: Why does the formula multiply by 2?
A: The factor of 2 accounts for both the "hot" and "neutral" (or positive and negative) conductors in the circuit.
Q5: How can I reduce voltage drop?
A: Use shorter wire runs, larger wire gauge (lower AWG number), or higher system voltage (24V instead of 12V).